              High and low temperature heating chamber BND-HGD1

              Product Description:Name:High and low temperature heating chamberType:BND-HGD1Purpose:It is applicatable for the testing of the indices of spacelight and aviation products,information eletronic instruments and meters,materials,and eletronic and eletrical compenents and parts in high-temperature,low-temperature,humid amd heat environment.
              Description

              Product Description:

              Name:High and low temperature heating chamber

              Type:BND-HGD1


              Purpose:

              It is applicatable for the testing of the indices of spacelight and aviation products,information eletronic instruments and meters,materials,and eletronic and eletrical compenents and parts in high-temperature,low-temperature,humid amd heat environment.


              Product Spec.and Technical parameter table

              model

              HGD1-02K

              HGD1-04K

              HGD1-10K

              HGD1-02K

              HGD1-04K

              HGD1-100K

              HGDL1-02K

              HGDL1-04K

              HGDL1-10K

              volume

              225

              408

              1000

              225

              408

              1000

              225

              408

              1000

              temperature range

              ﹣20~﹢150ºC

              ﹣40~﹢150ºC

              ﹣70~﹢150ºC

              humidity range

              25~98%RH

              temperature fluctuation

              ±0.5ºC(no-load)

              temperature deviation

              ±2.0ºC

              humidity deviation

              ±3.0%RH(>75%RH)±5.0%RH(≤75%RH)

              heating time

              ﹣20~﹢150ºC

              ﹣40~﹢150ºC

              ﹣70~﹢150ºC

              ≤60min

              cooling time

              ﹢20ºC~﹣20ºC

              ﹢20ºC~﹣40ºC

              ﹢20ºC~﹣70ºC

              ≤45min

              ≤60min

              ≤80min

              inside dimension(mm)

              W

              500

              600

              1000

              500

              600

              1000

              500

              600

              1000

              H

              750

              850

              1000

              750

              850

              1000

              750

              850

              1000

              D

              600

              800

              1000

              600

              800

              1000

              600

              800

              1000

              exterior dimension(mm)

              W

              910

              1010

              1410

              910

              1010

              1410

              910

              1010

              1410

              H

              1730

              1830

              1980

              1730

              1830

              1980

              1730

              1830

              1980

              D

              1173

              1373

              1588

              1173

              1373

              1588

              1173

              1373

              1588

              attemperation & humidifying

              Balance Thermal Control (BTC)

              Environment temperature

              +5ºC-+35ºC

              material

              shell

              Double cooling steel plate which sprayed with plastic.

              Inner dimension

              steel plate SUS 304

              insulate

              Rigid Polyurethane Foam + Glass fibre

              Regulating system

              heater

              nickel chromium heater

              humidifier

              stainless steel with heater (heating or humidity in the basin )& boiler

              blower

              centrifugal blower

              refrigeration compressor

              fully enclosed and low noise compressor

              refrigerant

              R404A

              R404A/R23

              cooling mode

              Mechanical compression, one-stage refrigeration refrigeration(air-cooling or water-cooling)

              Mechanical compression of  binary cascade  refrigeration(air-cooling or water-cooling)

              Controller

              monitor

              5.7 Inch color LCD panel

              Mode of operation

              procedure&set

              Method of Setting

              Touch the English or Chinese into the form

              procedure volume

              set the program of 120 groups of different conditions at the same,choose any group or parts to perform cycle work.In each group,1200 different temperature and time can be set at most(eEach section of the maximum is 999h59min).120 groups of procedures can be arbitrary connection,the most cycle can reach 999 times.

              Display resolution

              0.01ºC;0.1min;0.01%RH

              input

              Pt100 RTD

              Communication Interface

              R232 interface

              Method of control

              anti-windup PID

              Water supply

              method

              pumped

              water Tank

              built-in

              Quality of water

              resistance>500Ω

              Power Supply

              AC380(1±10%)V(50±0.5)Hz Three-phase four-wire+protective earth wire

              Maximum current(A)

              14

              14

              24

              14

              14

              25

              21

              21

              38

              installed capacity(KW)

              6

              6

              11

              7

              7

              12

              10

              10

              18

              Weight(KG)

              350

              350

              700

              350

              400

              750

              400

              500

              800

              safety device

              ELCB,Fan overheating protection,Compressor overpressure,overheating,OCP,Phase order protection,overheat, temperature fuse,Dry protector,Water system protection,Water break .