• <strong id="0sWBUZJ"></strong>
    1. <q id="0sWBUZJ"><style id="0sWBUZJ"></style></q>

        1. <abbr id="0sWBUZJ"><em id="0sWBUZJ"></em></abbr>

              ECTDS10-ISO Isolated Solution Conductivity Transmitter/Sensor

              Product Description:Name:ECTDS10-ISO Isolated Solution Conductivity Transmitter/SensorType:ECTDS10-ISOECTDS10 measures Conductivity, Salinity, TDS with temperature compensation.The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial,water processing, sewerage system, irrigation, smart agriculture etc.■ Conductivity, Salinity and TDS measurement with temperature compensation
              Description

              Product Description:

              Name:ECTDS10-ISO Isolated Solution Conductivity Transmitter/Sensor

              Type:ECTDS10-ISO

              ECTDS10 measures Conductivity, Salinity, TDS with temperature compensation.

              The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial,

              water processing, sewerage system, irrigation, smart agriculture etc.

              ■ Conductivity, Salinity and TDS measurement with temperature compensation

              ■ Isolated Sensor Input

              ■ With ABS or Stainless steel electrode

              ■ Output Interface with RS485, Voltage, Current

              ■ High accuracy with excellent stability

              ■ Reverse power protection and Built-in TVS/ESD protection


              Specifications

              Output Interface

              Analog Voltage 0-2V        

              (Output resistance ~0ohm)

              Analog Current 4-20mA        

              (Load Resistor<500ohm)

              RS485        

              Modbus-RTU

              Power Supply

              3.9-30V/DC

              12-30V/DC

              3.9-30V/DC

              Power Consumption(Idle)

              40mA@24V DC

              40mA@24V DC        

              (with 20mA output signal)

              40mA@24V DC

              Power Consumption(Max)

              80mA@24V DC

              100mA@24V DC        

              (with 20mA output signal)

              80mA@24V DC

              Start-up time

              < 2 seconds

              EC Measurement

              Isolated Sensor Input, Range: 0-5000us/cm, 10000us/cm, 20000us/cm        Resolution: 0-10000us/cm, 10us/cm; 100000-20000us/cm, 50us/cm

              Accuracy: 0-10000us/cm, ±3%; 10000-20000us/cm, ±5%

              EC temperature compensation: 0-50°C

              Temperature Measurement

              Range: -40~80°C, Resolution:0.1°C, Accuracy:±0.5°C

              IP Ratings

              Electrode:IP68; Transmitter:IP65

              Operating Temperature

              -40~85°C

              Installation

              Electrode:1/2″NPT screw threads; Transmitter:Mounting hole

              Cable Length

              Power and Signal Cable:2 meters or Customize; Electrode Cable:5 meters

              Dimension

              Electrode:1/2″NPT screw threads; Transmitter:128*70*42mm


              Ordering Information


              Parameters

              Code

              Comments

              Code 1:        

              Product Series

              ECTDS10-ISO

              ECTDS10-ISO isolated conductivity transmitter

              Code 2:        

              Measuring Parameters

              A

              Conductivity, Salinity and TDS

              Code 3:        

              Electrode

              A        

              B

              C

              ABS electrode        

              Stainless steel electrode

              Customize

              Code 4:        

              EC Range

              A        

              B

              C

              D

              E

              0-20000us/cm        

              0-10000us/cm

              0-5000us/cm

              0-2000us/cm

              Customize

              Code 5:        

              Power Supply

              A        

              B

              3.9-30V DC (applicable for RS485 and 0-2V output)        

              12-30V DC (applicable for 4-20mA output)

              Code 6:        

              Output Interface

              A        

              B

              C

              D

              E

              F

              G

              Analog Voltage 0-2V        

              Analog Current 4-20mA

              RS485,Modbus-RTU

              RS485,Modbus-RTU & Analog Voltage 0-2V

              RS485,Modbus-RTU & Analog Current 4-20mA

              SDI-12

              Customize

              Code 7:        

              Cable Length

              002        

              XXX

              Electrode Cable:5 meters , Power and Signal Cable:2 meters        

              Electrode Cable:5 meters , Power and Signal Cable:xxx meters

              Ordering Code Example:        

              ECTDS10-ISO isolated conductivity transmitter, ABS electrode, Conductivity Range 20000us/cm, Power Supply 3.9-30V DC, Output Interface RS485, Modbus-RTU, Power and Signal Cable Length 5 meters. Ordering Code is : ECTDS10-ISO-A A A A C 005

              1.jpg


              2.jpg


              ctfNyjavascript:void();
            1. <strong id="0sWBUZJ"></strong>
              1. <q id="0sWBUZJ"><style id="0sWBUZJ"></style></q>

                  1. <abbr id="0sWBUZJ"><em id="0sWBUZJ"></em></abbr>