              UL 94 Horizontal and vertical flame test apparatus BND-SPR

              The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample‘s ignition and burning. Sex and fire hazard.
              Description

              Product Description:

              Name:UL 94 Horizontal and vertical flame test apparatus

              Type:BND-SPR


              The Basic introduction of the flame tester:

              1. The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample's ignition and burning. Sex and fire hazard.

              2. HVR-4 horizontal and vertical combustion tester is mainly used for grading assessment of the flammability of V-0, V-1, V-2, HB, and 5V materials. It is suitable for the research, production and quality inspection departments of electrical and electronic products and their components such as lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motors, power tools, electronic instruments, electrical meters, electrical connectors and accessories. Used in insulation materials, engineering plastics or other solid combustible materials industries.


              Technical Parameter of flame test:

              Model

              BND-SPR   Horizontal vertical flame tester

              Kinds

               500W(5V class )

               50W(HB/V class)

              Test Flame

              500W(burning test for V-0,V-1,V-2  classification)

              50W(burning test for V-0,V-1,V-2 classification)

              Burner Tube

              Internal diameter: Φ 9.5mm±0.3mm

              Internal diameter: Φ 9.5mm±0.3mm, 

              Burning Angle

              0°,20°,45°

              0°,20°,45°

              Thermocouple

              Type K (Ni/Cr - Ni/Al)

              Type K (Ni/Cr - Ni/Al)

              Thermocouple Size 

              0.5 mm

              0.5 mm

              Standard Copper Block 

              9mm±0.01mm,

              weight:10g±0.05g before drilling.  

              5.5mm±0.01mm,

              weight:76g±0.01g before drilling.

              Time for Temperature to Increase

              From 100°C±5°C to 700°C±3°C; 54s±2s (preset)

              From 100°C±5°C to 700°C±3°C;

              44s±2s (preset)

              Gas Flow

              965±32ml/min

              105±10ml/min

              Gas Supply

              methane,min.98% purity

              methane,min.98% purity

              water-column 

              125m±5mm

              ‹10mm

              Test  Time

              54±2s

              44±2s

              Flame Height Indicator

              40±1mm

              20±1mm

              Volume Of Chamber

              >0.5m³, black interior

              >0.5m³, black interior

              Conform to standard

              UL94,IEC60695-11-3,IEC60695-11-20

              UL94,IEC60695-11-4,IEC60695-11-10