• <strong id="0sWBUZJ"></strong>
    1. <q id="0sWBUZJ"><style id="0sWBUZJ"></style></q>

        1. <abbr id="0sWBUZJ"><em id="0sWBUZJ"></em></abbr>

              Weather Meteorological Monitoring Station

              Daisy10 multi-parameter meteorological monitoring station is a multi-element automatic observation station. It can monitor conventional meteorological elements such as temperature, humidity, air pressure, wind direction, wind speed, soil temperature and humidity, and is widely used in meteorology, environmental protection, airports, agriculture and forestry, hydrology, military, storage, scientific research and other fields.
              Description

              Product Description:

              Name:Weather Meteorological Monitoring Station

              Type:Daisy10


              1. Application:

              Daisy10 multi-parameter meteorological monitoring station is a multi-element automatic observation station. It can monitor conventional meteorological elements such as temperature, humidity, air pressure, wind direction, wind speed, soil temperature and humidity, and is widely used in meteorology, environmental protection, airports, agriculture and forestry, hydrology, military, storage, scientific research and other fields.

              1) A variety of parameters are measured in one, the optional parameters include: air temperature, air humidity, dew point, atmospheric pressure, light intensity, carbon dioxide, soil moisture, soil temperature, soil conductivity, soil PH value, and leaf temperature, leaf humidity, Wind speed, wind direction, solar radiation, etc.

              2) The sensor has high accuracy, fast response, good interchangeability and reliable performance.

              3) DC wide range power supply, RS485 interface, standard Modbus protocol

              4) Multi-parameter integration, easy for system integration.

              5) Perfect protection circuit.


              2. Technical parameters:

              Signal output type

              RS485 interface

              Modbus protocol

              Supply voltage

              9-30V / DC DC

              Preheat time

              3 minutes

              Response time

              30 seconds (90%)

              Static power

              20mA @ 24V DC

              Operating environment

              Working temperature: -40 ~ 80 ℃

              Working humidity: 0 ~ 95% RH (no condensation)

              Installation method

              Bracket installation (with bracket mounting plate)

              Default cable length

              Power supply and communication cable: 2 meters, cable length can be customized.

              Connection method

              Wiring installation

              Dimensions

              Diameter * height = 140 * 300mm

              Air temperature

              Range: -40 ~ 80 ℃

              Accuracy: +/- 0.3 ℃

              Resolution: 0.01 ℃

              Air humidity

              Range: 0 ~ 100%

              Accuracy: +/- 4%

              Resolution: 0.01%

              Dew point

              Range: -40 ~ 80 ℃

              Accuracy: +/- 0.5 ℃

              Resolution: 0.01 ℃

              Air pressure

              Range: 300 ~ 1100mbar

              Accuracy: +/- 1mbar

              Resolution: 0.1mbar

              Illumination

              Range: 0 ~ 200,000 Lux

              Accuracy: +/- 5%

              Resolution: 0.1Lux

              carbon dioxide

              Range: 0 ~ 5000ppm

              Accuracy: +/- (50ppm + 5% reading value)

              Resolution: 1ppm

              Soil temperature

              Range: -40 ~ 80 ℃

              Accuracy: +/- 0.5 ℃

              Resolution: 0.01 ℃

              Soil Moisture

              Range: 0 ~ 100%

              Accuracy: 2% within 0-50%, 3% within 50-100%

              Resolution: 0.01%

              Soil conductivity

              Range: 0 ~ 20000us / cm

              Accuracy is +/- 3% in the range of 0 ~ 10000us / cm; +/- 5% in the range of 10000 ~ 20000us / cm

              Resolution: 1us / cm

              Leaf temperature

              Range: -40 ~ 80 ℃

              Accuracy: +/- 0.5 ℃

              Resolution: 0.01 ℃

              Foliar humidity

              Range: 0 ~ 100%

              Accuracy: +/- 5%

              Resolution: 0.01%

              Soil pH

              Range: 0 ~ 14PH

              Accuracy: +/- 0.1PH

              Resolution: 0.01PH

               

              3. Dimension:

              Diameter: 140mm, height: 300mm


              4. Model selection:


              Code number

              code

              Code description

              Code 1: Product series

              Daisy10

              Daisy10 multi-parameter weather monitoring station

              Code 2: Supply voltage

              A

              9-30V DC

              Code 3: Output signal

              A

              RS485 interface, Modbus protocol

              Code 4: Communication and power cable length

              002

              XXX

              2 meters long

              Customized, XXX is any line length (unit: m)

              Code 5: Installation method

              A

              X

              Bracket installation

              This item is not needed

              Code 6: Air temperature

              A

              X

              Range: -40 ~ 80 ℃

              This item is not needed

              Code 7: Air humidity

              A

              X

              Range: 0 ~ 100%

              This item is not needed

              Code 8: Dew point

              A

              X

              Range: -40 ~ 80 ℃

              This item is not needed

              Code 9: Atmospheric pressure

              A

              X

              Range: 300 ~ 1100mbar

              This item is not needed

              Code 10: Illumination

              A

              X

              Range: 0 ~ 200,000 Lux

              This item is not needed

              Code 11: Carbon dioxide

              A

              B

              C

              D

              E

              F

              X

              Range: 0-1000ppm

              Range: 0-2000ppm

              Range: 0-5000ppm

              Range: 0-10000ppm

              Range: 0-30000ppm

              Range: 0-50000ppm

              This item is not needed

              Code 12: Soil temperature

              A

              X

              Z

              Range: -40 ~ 80 ℃

              This item is not needed

              Customized (parameters such as cable length)

              (Default 2 meters long)

              A

              X

              Z

              Range: 0 ~ 100%

              This item is not needed

              Customized (parameters such as cable length)

              Code 13: Soil moisture

              A

              X

              Z

              Range: 0 ~ 20000us / cm

              This item is not needed

              Customized (parameters such as cable length)

              (Default 2 meters long)

              A

              X

              Z

              Range: -40 ~ 80 ℃

              This item is not needed

              Customized (parameters such as cable length)

              Code 14: Soil conductivity

              A

              X

              Z

              Range: 0 ~ 100%

              This item is not needed

              Customized (parameters such as cable length)

              (Default 2 meters long)

              A

              X

              Z

              Range: 0 ~ 14PH

              This item is not needed

              Customized (parameters such as cable length)

              Model example:

              Daisy10 multi-parameter weather monitoring station, 9-30V DC power supply, RS485 interface, Modbus protocol, power supply and communication cable 2 meters, bracket installation, air temperature, air humidity, dew point, atmospheric pressure measurement The selection code is: Daisy10-AA002AAAAAXXXXXXXX