• <strong id="0sWBUZJ"></strong>
    1. <q id="0sWBUZJ"><style id="0sWBUZJ"></style></q>

        1. <abbr id="0sWBUZJ"><em id="0sWBUZJ"></em></abbr>

              Photovoltaic Auto safety comprehensive tester

              Product Description:Name:Photovoltaic Auto safety comprehensive testerType:BND-CS9933EG-15Standards: IEC61730; IEC61215; IEC 61646Description of PV safety tester:Photovoltaic safety tester is used to test PV module, cable, connector, terminal box, …etc which can deal with high voltage and high sensitivity insulation test. There are two functions that are high voltage test and insulation resistance test in total.
              Description

              Product Description:

              Name:Photovoltaic Auto safety comprehensive tester

              Type:BND-CS9933EG-15

              Standards: IEC61730; IEC61215; IEC 61646


              Description of PV safety tester:

              Photovoltaic safety tester is used to test PV module, cable, connector, terminal box, …etc which can deal with high voltage and high sensitivity insulation test. There are two functions that are high voltage test and insulation resistance test in total.

              According to the IEC61730 standard(photovoltaic module safety qualification—part I: Requirements for construction which describes the fundamental construction requirements for photovoltaic modules in order to provide safe electrical and mechanical operation during their expected lifetime), the definition of PV module application is divided into A, B, C.

              The current measuring terminal can choose the grounding mode or the floating mode. Insulation voltage withstand test of photovoltaic module is based on the application of IEC61215/61646 and the maximum voltage of the system.

              Maximum test voltage for the application class A:2000V plus 4 times the maximum system voltage

              For the maximum voltage application category B:1000V system 2 times

              According to the calculation of a maximum voltage of 8000V, CS9923GS, CS9923G is based on this standard production

              According to the calculation of the maximum voltage B 6000V, CS9922G, CS9922GS is based on this standard production


              Performance characteristics:

              ◆With safety anti-electric wall function, it can automatically detect whether the input power is correct

              ◆For photovoltaic system panels, controllers, and battery packs

              ◆After the DC withstand voltage and insulation resistance tests are completed, the tester can quickly discharge within 0.2 seconds to protect the safety of the operator

              ◆With current lower limit alarm function, it can prevent the open circuit of the test line from causing misjudgment of the tested components during the test. The output voltage has voltage upper limit and voltage lower limit alarm functions

              ◆With keyboard lock function to prevent the operator from modifying the test parameters and ensure that the tested object is tested according to the set parameters

              ◆Linear power amplifier drives the output of sinusoidal voltage (current), and the crest factor is within the range of 1.3 to 1.5

              ◆Adopts 240*64 graphic LCD display and humanized interface design

              ◆With Chinese and English display interfaces, it can meet the different needs of different users.

              ◆Test parameters can be saved in advance: 30 files can be set, and each file can have 99 test steps

              ◆Optional RS232, RS485, USB interface, standard PLC interface

              pv-auto-safety-tester (1).jpg


              The Specification of the PV safety test system:

              Model

              BND-CS9933EG-15









              ACW


              The output voltage

              Range

              0.050kV~6.500kV

              Accuracy

              ±(1.5% reading + 5V)

              Resolution

              1V

              Maximum output power

              130VA(6.500kV/20mA)

              Maximum rated current

              20mA

              Lower current range

              0~20mA, 0=no lower limit

              Current range

              200uA, 2mA, 20mA

              Output waveform

              Sine wave

              Output waveform distortion

              ≤2% (no load or pure resistive load)

              Crest factor

              1.3~1.5

              Output signal type

              DDS+ amplifier

              Voltage rise time

              0.3s~999.9s 0=voltage rise time off

              Test time

              0.3s~999.9s 0=continuous test

              Voltage fall time

              0.3s~999.9s 0=voltage fall time off

              Interval time

              0.0s~999.9s 0=interval time off

              Output voltage mode

              N-mode, G-mode







              DCW






              The output voltage

              Range

              0.050kV~6.500kV

              Accuracy

              ±(1.5%Value +5V)

              Resolution

              1V

              Maximum output power

              65W(6.500kV/10mA)

              Maximum rated current

              10mA

              Current range

              2uA、20uA、200uA、2mA、10mA

              Ripple factor

              ≤5%

              Discharge time

              ≤200ms

              Maximum charge current

              10mA

              Voltage rise time

              0.3s~999.9s 0=voltage rise time off

              Test time

              0.3s~999.9s 0=continuous test

              Voltage drop time

              0.3s~999.9s 0=voltage drop time off

              Interval time

              0.0s~999.9s 0=interval time off

              Delay alarm time

              0.3s~999.9s 0=delay alarm time off

              Output voltage mode

              N mode, G mode


              IR



              The output voltage

              Range

              0.050kV~1.500kV

              Accuracy

              ±(1.5% reading +5V)

              Resolution

              1V

              Maximum upper limit setting value

              50.00GΩ




              Maximum and minimum setting values

              50.00GΩ

              Minimum setting values

              1MΩ

              Voltage rise time

              0.3~999.9s 0=voltage rise time off

              Test time

              0.3s~999.9s 0=continuous test

              Interval time

              0.0s~999.9s 0=interval time off

              Automatic gear switching

              Can be set to on or off

              Discharge time

              ≤200ms







              GR


              Output current

              Range

              3.00A~52.00A(DC)

              Accuracy

              ±(1.5% Value +0.2A)

              Resolution

              0.01A

              Maximum output power

              250W(50A/0.10Ω)

              Maximum output current

              50AW

              Resistance upper limit setting value

              40A x150mW

              Set current value

              Output waveform

              Sine wave

              Output waveform distortion

              ≤2% (no load or pure resistive load)

              Crest factor

              1.3~1.5

              Output signal type

              DDS+power amplifier

              Test time

              0.3s~999.9s 0=continuous test

              Interval time

              0.3s~999.9s 0=interval time off

              Voltmeter


              Range

              0.050kV~6.500kV

              0.050kV~6.500kV

              0.050kV~6.500kV

              0.050kV~6.500kV

              Accuracy

              ±(1.5% reading +5V)

              Resolution

              1V

              Display value

              RMS value



              Withstand voltage ammeter

              Measure range

              AC

              0 ~ 20mA

              DC

              0 ~ 10mA


              Resolution

              AC

              200uA: 0.1uA, 2mA: 1uA, 20mA: 10uA

              DC

              2uA: 0.001uA, 20uA: 0.01uA, 200uA: 0.1uA, 2mA: 1uA,

              10mA: 10uA

              Measurement accuracy

              ≥2mA: ±(1.5%+5 digits), <2mA: ±(2%+5 digits)

              Offset function

              The current of the test leads and accessories can be subtracted.

              Test mode

              GND mode: RETURN terminal connected to the chassis

              FLOAT mode: RETURN terminal not connected to the chassis


              Measurement range

              1MΩ~50000MΩ


              Resolution

              1MΩ~9.999MΩ:0.001MΩ,10MΩ~99.99MΩ:0.01MΩ,

              100MΩ~999.9MΩ:0.1MΩ,1000MΩ~9999MΩ:1MΩ

              10GΩ~50GΩ:10MΩ

              Insulation resistance meter



              Accuracy

              0.100kV~0.200kV:1MΩ~999MΩ ±5%,1000MΩ~3000MΩ ±10%

              0.201kV~0.499kV:1MΩ~999MΩ ±5%,1000MΩ~5000MΩ ±10%

              0.500kV~1.000kV:1MΩ~999MΩ ±5%,1000MΩ~9999MΩ ±10%

              10000MΩ~50000MΩ ±15%

              Ground current meter

              Measuring range

              3.00A~52.00A

              Resolution

              0.01A

              Accuracy

              ±(1.5% of reading + 0.2A)

              Display value

              RMS value

              Ground resistance meter

              Range

              0~510mΩ

              Accuracy

              When the current is less than 5.00A, it is ± (3% of reading + 3mΩ) When the current is ≥ 5.00A, it is ± (2% of reading + 2mΩ)

              Resolution

              0.1mΩ

              Measuring method

              Four-terminal method

              Timer

              Range

              0~999.9s

              Resolution

              0.1s

              Accuracy

              ±(0.1%+50ms)